SL-701A Ionizing Air Curtain

SL-701A Ionizing Air Curtain

Model No.︰SL-701A

Brand Name︰SLD

Country of Origin︰China

Unit Price︰-

Minimum Order︰1 pc

Inquire Now

Product Description

Product Details:
SL-701A Ionizing Air Curtain can produce considerable air flows carrying both positive and negative charges, which can neutralize electric charges on the object. When the object surface is negatively charged, it will absorb positive charges from air flow; when positively charged, it will absorb negative charges from air flow. In this way, the electrostatic charges will be neutralized and thus eliminated from the object surface.

Ionization element of SL-701A Ionizing Air Curtain: Under the effect of high voltage and low current produced by the high-voltage generator, the ionization element will form a steady high-voltage electric field, where air will be ionized to ions. Such ions will be carried by air flow onto the object surface and neutralize the electrostatic charges therefrom.

The electrostatic elimination function of SL-701A Ionizing Air Curtain can solve the production problems caused by electrostatic effect, such as dust absorption caused by static electricity, adhesion incurred during plastic processing, small parts jumping incurred due to electrostatic repulsion.

Product Features:

1. The air flow provided by drum-type blower blade can neutralize electrostatic charges quickly.
2. Large-area coverage of ion stream.
3. Built-in electrostatic eliminator available.
4. Ionizing Air Curtain is subject to good grounding protection.

Technical parameters:

 

Input voltage

220V/50Hz   or   110V/60Hz

power

350W

Output voltage

≤±30V  (30 cm distance measurement)

Eliminate static time

≤1S    (30 cm distance measurement)

Ozone production

<0.03PPM  (15cm distance measurement)

noise

<65dB

Size(mm)

Power(w)

Export wind speed(m/s)

Average noise leveldB(a)

Weight (kg)

600×190×220

160

11-15

50

11.85

900×190×220

230

11-15

51

15.15

1200×190×220

345

11-15

52

18.45

1500×190×220

390

11-15

53

22.25

1800×190×220

410

11-15

54

26.55

Shell material

aluminum

surface

Lacquer that bake

Test results:

 

Decay Test Conditions

Operating Voltage:110V/220V  Testing Voltage:1KV to 100V

Temperature:22℃

Distance

 

600mm

1000mm

2000mm

Decay time

positive

0.5s

1.0s

2.0s

Negative

0.6s

1.20s

2.1s


 

 

 

 

 

Remarks:
1. The test distance is measured in mm, while the neutralization time is measured in s.
2. The test data are subject to the test results of ME268A Electrostatic Tester.
3. The test data vary with the ambient temperature during testing.