Features:
1. neutralize charges quickly.
2. The bowered area of ionizing airflow is big.
3. Safety Induction No shock.
4. The air nozzle with good Ground Protection.
Technical parameters:
Operating Voltage
|
4.6KV
|
Current Consumption
|
200uA
|
Operating Temperature
|
-10~50°C
|
Weight
|
0.42Kg
|
HV Cable length
|
2 Meters
|
Air pressure
|
5~7Kg
|
Air velocity
|
10m/sec
|
Test Results:
Testing Conditions
|
Test voltage-5KV-500V
Operating Voltage-4.6KV
Temperature:22°C
|
Distance
|
|
30mm
|
90mm
|
150mm
|
Decay time
|
Positive
|
0.1s
|
0.4s
|
0.8s
|
Negative
|
0.1s
|
0.3s
|
0.7s
|